The Dynamic Exertion Test for Sport-Related Concussion: A Comparison of Athletes at Return-to-Play and Healthy Controls.
Аннотация
PURPOSE: To describe the Dynamic Exertion Test (EXiT) by comparing physiological, performance, and clinical outcomes between athletes medically cleared following sport-related concussion (SRC) and healthy controls.
METHODS
One hundred four (female = 41, 39.4%) participants (14-21 y of age) including 52 medically cleared for return to play at 21.48 (15.40) days following SRC and 52 healthy athletes completed the EXiT involving (1) 12-minute aerobic component and (2) 18-minute dynamic component including 2 functional movement and 5 change-of-direction (COD) tasks. Physiological (heart rate and blood pressure), clinical (endorsed symptoms and rating of perceived exertion), and performance (COD-task completion time and errors) outcomes were collected throughout EXiT. Participants also completed the Postconcussion Symptom Scale and vestibular/ocular motor screening before EXiT. Independent-samples t tests were used to compare groups on resting heart rate and blood pressure, COD-task completion time, and Mann-Whitney U tests on Postconcussion Symptom Scale, vestibular/ocular motor screening, and EXiT symptoms, rating of perceived exertion, and errors.
RESULTS
COD-task completion time and resting systolic blood pressure and heart rate were similar between groups (P > .05). SRC reported greater rating of perceived exertion during the aerobic component (P < .05) and lower total dizziness (P = .003) and total symptoms (P = .021) during EXiT and had lower near point of convergence distance (P < .001) and total symptoms (P = .007) for vestibular/ocular motor screening than healthy athletes.
CONCLUSION
Physiological, performance, and clinical EXiT outcomes were equivocal between athletes at medical clearance following SRC and healthy controls. The multidomain EXiT may help to inform safe return-to-play decision making post-SRC.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.