ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2022

Electrical Impedance as a Noninvasive Metric of Quality in Allografts Undergoing Normothermic Ex Vivo Lung Perfusion.

СтатьяПоддержка исследования: вне правительства СШАПоддержка правительства СШАПоддержка NIH: внешняя программаНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Peterson Danielle M, Beal Eliza W, Reader Brenda F, Dumond Curtis, Black Sylvester M, Whitson Bryan A

Аннотация

Ex vivo lung perfusion (EVLP) increases the pool of suitable organs for transplant by facilitating assessment and repair at normothermia, thereby improving identification of quality of marginal organs. However, there exists no current objective approach for assessing total organ edema. We sought to evaluate the use of electrical impedance as a metric to assess total organ edema in lungs undergoing EVLP. Adult porcine lungs (40 kg) underwent normothermic EVLP for 4 hours. To induce varying degrees of lung injury, the allografts were perfused with either Steen, a modified cell culture media, or 0.9% normal saline. Physiologic parameters (peak airway pressure and compliance), pulmonary artery and left atrial blood gases, and extravascular lung water measurements were evaluated over time. Wet-to-dry ratios were evaluated postperfusion. Modified Murray scoring was used to calculate lung injury. Impedance values were associated with lung injury scores ( p = 0.007). Peak airway pressure ( p = 0.01) and PaO 2 /FiO 2 ratios ( p = 0.005) were both significantly associated with reduced impedance. Compliance was not associated with impedance ( p = 0.07). Wet/dry ratios were significantly associated with impedance and Murray Scoring within perfusion groups of Steen, Saline, and Modified Cell Culture ( p = 0.0186, 0.0142, 0.0002, respectively). Electrical impedance offers a noninvasive modality for measuring lung quality as assessed by tissue edema in a porcine model of normothermic EVLP. Further studies evaluating the use of impedance to assess organ edema as a quality marker in human clinical models and abdominal organs undergoing ex vivo perfusion warrant investigation.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты