MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/0255-0857.103757

Медицинская библиотека · Indian journal of medical microbiology · 2012

Development and evaluation of reverse-transcription loop-mediated isothermal amplification for rapid detection of human immunodeficiency virus type 1.

Zhao Xihong, Chen Xiaoping, Zhang Youhong, He Xiaowei, Li Wenmei, Shi Lei, Chen Xingzhou, Xu Zhenbo, Zhong Nanjing, Ji Guiyuan, Yang Liansheng, Wang Jihua

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: The objective of this study was to establish a reverse-transcription loop-mediated isothermal amplification (RT-LAMP) method for rapid detection of human immunodeficiency virus type 1 (HIV-1).

MATERIALS AND

METHODS

The HIV-1 integrase gene region was selected because it was a conserved part of the HIV-1 genome. Six primers specific to eight regions of the HIV-1 integrase gene were designed. A total of 171 samples (18 HIV-1 confirmed positive samples and 153 serum specimens were collected in this study) were tested by RT-LAMP and reverse-transcription polymerase chain reaction (RT-PCR). After amplification in an isothermal water bath for 45 min, samples containing HIV-1 generated the expected ladder-like products while other viruses generated no product.

RESULTS

The sensitivity and specificity of the RT-LAMP assay were evaluated by comparison with RT-PCR. The assay was significantly more sensitive than normal gel-based RT-PCR.

CONCLUSION

Because it is specific and simple, the RT-LAMP assay can be widely applied in clinical laboratories for rapid detection of HIV-1.

Для цитирования: Zhao Xihong, Chen Xiaoping, Zhang Youhong, He Xiaowei, Li Wenmei, Shi Lei, Chen Xingzhou, Xu Zhenbo, Zhong Nanjing, Ji Guiyuan, Yang Liansheng, Wang Jihua. Development and evaluation of reverse-transcription loop-mediated isothermal amplification for rapid detection of human immunodeficiency virus type 1.. Indian journal of medical microbiology. 2012. DOI: 10.4103/0255-0857.103757.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.