DOI 10.1021/ac302513f

Медицинская библиотека · Analytical chemistry · 2012

Discrete frequency infrared microspectroscopy and imaging with a tunable quantum cascade laser.

Kole Matthew R, Reddy Rohith K, Schulmerich Matthew V, Gelber Matthew K, Bhargava Rohit

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

Fourier-transform infrared (FT-IR) imaging is a well-established modality but requires the acquisition of a spectrum over a large bandwidth, even in cases where only a few spectral features may be of interest. Discrete frequency infrared (DF-IR) methods are now emerging in which a small number of measurements may provide all the analytical information needed. The DF-IR approach is enabled by the development of new sources integrating frequency selection, in particular of tunable, narrow-bandwidth sources with enough power at each wavelength to successfully make absorption measurements. Here, we describe a DF-IR imaging microscope that uses an external cavity quantum cascade laser (QCL) as a source. We present two configurations, one with an uncooled bolometer as a detector and another with a liquid nitrogen cooled mercury cadmium telluride (MCT) detector and compare their performance to a commercial FT-IR imaging instrument. We examine the consequences of the coherent properties of the beam with respect to imaging and compare these observations to simulations. Additionally, we demonstrate that the use of a tunable laser source represents a distinct advantage over broadband sources when using a small aperture (narrower than the wavelength of light) to perform high-quality point mapping. The two advances highlight the potential application areas for these emerging sources in IR microscopy and imaging.

Для цитирования: Kole Matthew R, Reddy Rohith K, Schulmerich Matthew V, Gelber Matthew K, Bhargava Rohit. Discrete frequency infrared microspectroscopy and imaging with a tunable quantum cascade laser.. Analytical chemistry. 2012. DOI: 10.1021/ac302513f.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.