MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1373/clinchem.2015.253781

Медицинская библиотека · Clinical chemistry · 2016

Screening Method for M-Proteins in Serum Using Nanobody Enrichment Coupled to MALDI-TOF Mass Spectrometry.

Kohlhagen Mindy C, Barnidge David R, Mills John R, Stoner Joshua, Gurtner Kari M, Liptac Andrea M, Lofgren Denise I, Vanderboom Patrick M, Dispenzieri Angela, Katzmann Jerry A, Willrich Maria A V, Snyder Melissa R, Murray David L

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Current recommendations for screening for monoclonal gammopathies include serum protein electrophoresis (PEL), imunofixation electrophoresis (IFE), and free light chain (FLC) ratios to identify or rule out an M-protein. The aim of this study was to examine the feasibility of an assay based on immunoenrichment and MALDI-TOF-MS (MASS-SCREEN) to qualitatively screen for M-proteins.

METHODS

Serum from 556 patients previously screened for M-proteins by PEL and IFE were immunopurified using a κ/λ-specific nanobody bead mixture. Following purification, light chains (LC) were released from their heavy chains by reduction. MALDI-TOF analysis was performed and the mass-to-charge LC distributions were visually examined for the presence of an M-protein by both unblinded and blinded analysts.

RESULTS

In unblinded analysis, MASS-SCREEN detected 100% of the PEL-positive samples with an analytical sensitivity and specificity of 96% and 81% using IFE positivity as the standard. In a blinded analysis using 6 different laboratory personnel, consensus was reached in 92% of the samples. Overall analytical sensitivity and specificity were reduced to 92% and 80%, respectively. FLC ratios were found to be abnormal in 28% of MASS-SCREEN-negative samples, suggesting FLC measurements need to be considered in screening.

CONCLUSIONS

MASS-SCREEN could replace PEL in a panel that would include FLC measurements. Further studies and method development should be performed to validate the clinical sensitivity and specificity and to determine if this panel will suffice as a general screen for monoclonal proteins.

Для цитирования: Kohlhagen Mindy C, Barnidge David R, Mills John R, Stoner Joshua, Gurtner Kari M, Liptac Andrea M, Lofgren Denise I, Vanderboom Patrick M, Dispenzieri Angela, Katzmann Jerry A, Willrich Maria A V, Snyder Melissa R, Murray David L. Screening Method for M-Proteins in Serum Using Nanobody Enrichment Coupled to MALDI-TOF Mass Spectrometry.. Clinical chemistry. 2016. DOI: 10.1373/clinchem.2015.253781.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.