MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0015-0282(16)56268-2

Медицинская библиотека · Fertility and sterility · 1993

Complications associated with the absorption of hysteroscopic fluid media.

Witz C A, Silverberg K M, Burns W N, Schenken R S, Olive D L

СтатьяОбзорПеревод в очереди

Аннотация

OBJECTIVES

To review the literature concerning complications resulting from absorption of hysteroscopic fluid distension media and to describe methods to treat and prevent these complications.

DESIGN

All pertinent literature on fluid distension media used for endoscopy, as well as relevant reports concerning the management of fluid and electrolyte imbalance, was reviewed.

RESULTS

The absorption of large volumes of electrolyte-free, low-viscosity fluid may result in volume overload with water intoxication. Volume overload may cause pulmonary edema, and water intoxication may lead to hyponatremia, hypo-osmolarity, and cerebral edema. In contrast, the absorption of dextran-70 may cause volume overload secondary to the oncotic effect of intravascular dextran. Dextran-70 has been associated with anaphylaxis and coagulation disorders.

TREATMENT: The use of diuretics is advocated. Urine output must be closely monitored. Judicious correction of electrolyte imbalance will prevent morbidity.

PREVENTION: Meticulous attention to intraoperative fluid balance is imperative. A multichannel hysteroscope is necessary to keep intrauterine pressure low. Extensive surgical procedures may need to be performed in stages.

CONCLUSIONS

Severe volume overload and electrolyte imbalance may result from fluid absorption during operative hysteroscopy. Most complications may be avoided by closely monitoring fluid balance intraoperatively.

Для цитирования: Witz C A, Silverberg K M, Burns W N, Schenken R S, Olive D L. Complications associated with the absorption of hysteroscopic fluid media.. Fertility and sterility. 1993. DOI: 10.1016/s0015-0282(16)56268-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.