MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.talanta.2025.128195

Медицинская библиотека · Talanta · 2025

Integrated duplex reverse transcription-recombinase aided amplification (RT-RAA) and lateral flow assay (LFA) for rapid simultaneous detection of Zika virus and Japanese encephalitis virus in single reaction format.

Cong Haolong, Han Xiaodong, Lv Mengyuan, Chang Yutong, Wang Xinyi, Lei Rong

СтатьяПеревод в очереди

Аннотация

Zika virus (ZIKV) and Japanese encephalitis virus (JEV), two consequential mosquito-borne flaviviruses, induce severe systemic and neurotropic-encephalitic pathologies with overlapping symptoms profiles, complicating differential diagnosis in co-endemic regions. To address this critical challenge, we developed a dual reverse-transcription recombinase-aided amplification (RT-RAA) coupled with duplex lateral flow assay (LFA) platform for rapid, equipment-free co-detection of ZIKV and JEV in a single reaction tube. The assay achieved isothermal amplification at 39 °C within 40 min using a field-deployable incubator. The limit of detection (LOD) reached as low as 8.5 copies ZIKV RNA, and 1.1 copies JEV RNA in single pathogen detection, while 110 copies JEV RNA in co-detection mode. This technological advance bridges the critical sensitivity gap between lab-based PCR and conventional rapid tests, enabling first-line healthcare responders to conduct precision diagnostics in non-laboratory settings from rural clinics to mobile outbreak response units.

Для цитирования: Cong Haolong, Han Xiaodong, Lv Mengyuan, Chang Yutong, Wang Xinyi, Lei Rong. Integrated duplex reverse transcription-recombinase aided amplification (RT-RAA) and lateral flow assay (LFA) for rapid simultaneous detection of Zika virus and Japanese encephalitis virus in single reaction format.. Talanta. 2025. DOI: 10.1016/j.talanta.2025.128195.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.