Current eye research · 2009
Femtosecond laser-assisted keratoplasty: laboratory studies in eye bank eyes.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Malta João Baptista, Soong H Kaz, Shtein Roni, Banitt Michael, Musch David C, Sugar Alan, Mian Shahzad I
Аннотация
PURPOSE: To optimize the surgical technique for performing femtosecond laser-assisted keratoplasty (FLAK) using the IntraLase FS to cut both recipient and donor cornea buttons in eye bank globes.
METHODS: FLAK was performed in six globes and six corneoscleral buttons for each of the following trephination patterns: top hat, mushroom, tongue-groove, and vertical. Manual trephination was performed as control. The wound integrity was tested in incisions closed with 8 sutures, 8 sutures with fibrin adhesive, and 16 sutures by measuring the intraocular pressure required to produce graft-host wound leakage (IOP(L)). Light microscopy (LM) and scanning electron microscopy (SEM) were performed to assess cut surface quality and graft-host interface regularity.
RESULTS: Mushroom and top hat FLAK had significantly higher IOP(L) than vertical or manual trephination (p < 0.0001) for wounds closed with 16 sutures. There was no difference in IOP(L) between top hat, mushroom, and tongue-groove FLAK in wounds closed with 8 sutures with fibrin adhesive (p > 0.75). LM and SEM demonstrated cut surfaces with good quality and smooth edges.
CONCLUSIONS: These preliminary studies show that FLAK produces precise trephination cuts of superior wound strength and stability to that of manual trephination. Adjuvant fibrin glue may further improve wound integrity.
METHODS: FLAK was performed in six globes and six corneoscleral buttons for each of the following trephination patterns: top hat, mushroom, tongue-groove, and vertical. Manual trephination was performed as control. The wound integrity was tested in incisions closed with 8 sutures, 8 sutures with fibrin adhesive, and 16 sutures by measuring the intraocular pressure required to produce graft-host wound leakage (IOP(L)). Light microscopy (LM) and scanning electron microscopy (SEM) were performed to assess cut surface quality and graft-host interface regularity.
RESULTS: Mushroom and top hat FLAK had significantly higher IOP(L) than vertical or manual trephination (p < 0.0001) for wounds closed with 16 sutures. There was no difference in IOP(L) between top hat, mushroom, and tongue-groove FLAK in wounds closed with 8 sutures with fibrin adhesive (p > 0.75). LM and SEM demonstrated cut surfaces with good quality and smooth edges.
CONCLUSIONS: These preliminary studies show that FLAK produces precise trephination cuts of superior wound strength and stability to that of manual trephination. Adjuvant fibrin glue may further improve wound integrity.