DOI 10.1177/0310057x9001800422
Positioning central venous catheters--a prospective survey.
Аннотация
This paper reports the results of a prospective survey of 266 attempted central venous catheterisations by various routes, evaluating their success rate and incidence of immediate complications and attempts to demonstrate a relationship between patient height in centimetres (H) and ideal catheter length. The overall rate of intrathoracic placement was 230 from 239 catheterisations (96%) after 266 attempts (86%). Of these 230 catheters, 54 terminated in the right atrium (24%). To avoid right atrial placement with its well documented risk of cardiac tamponade, it is recommended that right infraclavicular subclavian catheters are inserted to H/10-2 cm, right internal or external jugular catheters to H/10 cm and left external jugular catheters to H/10 + 4 cm.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.