MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1148/radiology.177.2.2217768

Медицинская библиотека · Radiology · 1990

Pinch-off syndrome: a complication of implantable subclavian venous access devices.

Hinke D H, Zandt-Stastny D A, Goodman L R, Quebbeman E J, Krzywda E A, Andris D A

СтатьяПеревод в очереди

Аннотация

Implantable central venous access devices placed via the subclavian vein may become obstructed by thrombosis, impingement against a vein wall, or compression between the clavicle and first rib. The latter has been termed pinch-off syndrome (POS). Eleven patients with POS were studied, including one whose catheter had fractured and one whose catheter had fragmented. They were compared with 22 matched control patients and 100 consecutive routine clinic patients. Each catheter was graded: 0 = normal, 1 = abrupt change in course with no luminal narrowing, 2 = luminal narrowing, and 3 = complete catheter fracture. POS was present in most (eight of 11) cases within 3 weeks after placement. A grade 1 catheter was common (33%) among control subjects, but grades 2 and 3 were uncommon (1%). Catheter fracture or fragmentation was seen in two of five cases with long-term (greater than 3 weeks) pinching (grade 2 catheter). The following conclusions were reached: Grade 2 represents significant catheter compression and the potential for serious complications. Grade 1 is of uncertain clinical significance, due to its high prevalence in control subjects.

Для цитирования: Hinke D H, Zandt-Stastny D A, Goodman L R, Quebbeman E J, Krzywda E A, Andris D A. Pinch-off syndrome: a complication of implantable subclavian venous access devices.. Radiology. 1990. DOI: 10.1148/radiology.177.2.2217768.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.