MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00005537-199908000-00021

Медицинская библиотека · The Laryngoscope · 1999

Increased stability of airflow following botulinum toxin injection.

Finnegan E M, Luschei E S, Gordon J D, Barkmeier J M, Hoffman H T

Клиническое исследованиеСтатьяРандомизированное исследованиеПоддержка службы здравоохранения СШАОбзорПеревод в очереди

Аннотация

OBJECTIVES

The purpose of this study was to determine whether stability of airflow, as well as mean airflow, increased following botulinum toxin injection to laryngeal and extralaryngeal muscles in persons with spasmodic dysphonia (SD), some with associated vocal tremor (VT).

STUDY

DESIGN

Aerodynamic data were collected from five subjects before and at 2, 4, and 8 weeks after they received treatment by each of two different arms in an injection protocol in a crossover study. One arm of the protocol involved treatment of the thyroarytenoid muscles only. The other arm involved treatment of both the thyroarytenoid muscles and the strap muscles.

METHODS

Measures of mean airflow and coefficient of variation (COV) of airflow during phonation were obtained. A decrease in the COV of airflow would indicate increased stability of phonatory airflow.

RESULTS

Before treatment, all subjects with SD/VT exhibited mean airflows that were similar to controls. The COV of airflow ranged from normal to substantially elevated. Following botulinum injection, mean airflow characteristically increased and COV of airflow decreased.

CONCLUSIONS

This finding suggests there is a change in the type, as well as the level, of activity in the muscles of speech production following botulinum toxin injection. The increase in airflow stability identified could be due to increased stability of the laryngeal system and possibly of the respiratory system as well.

Для цитирования: Finnegan E M, Luschei E S, Gordon J D, Barkmeier J M, Hoffman H T. Increased stability of airflow following botulinum toxin injection.. The Laryngoscope. 1999. DOI: 10.1097/00005537-199908000-00021.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.