MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-026-42316-2

Медицинская библиотека · Scientific reports · 2026

Multicenter ex vivo evaluation of an α-mannosidase-targeted fluorescent probe for intraoperative margin assessment in breast cancer.

Ueo Hiroki, Ueo Hiroaki, Doi Takako, Yamaguchi Miki, Akashi-Tanaka Sadako, Takamaru Tomoko, Tsuda Hitoshi, Moriya Takuya, Yamaguchi Rin, Kozuka Yuji, Sasaki Takeshi, Gamachi Ayako, Kai Yuichiro, Kubota Yoko, Kunii Shun, Nagamori Yui, Fujita Kyohhei, Urano Yasuteru, Ando Yuki, Mimori Koshi, Masuda Takaaki

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

Determining an accurate intraoperative margin is essential in breast-conserving surgery (BCS) for breast cancer. This multicenter study assessed the diagnostic potential of a novel fluorescent probe targeting α-mannosidase, named the α-Man probe, in evaluating intraoperative margins. We analyzed 274 resected breast tissue samples, including malignant and benign lesions, across four institutions. Fluorescence intensity (FI) was measured 5 and 20 min following the application of the α-Man probe. Receiver operating characteristic analysis defined definitive thresholds for changes in FI (ΔFI), maintaining false positive and false negative rates at ≤ 3%. Diagnostic performance was also compared with a γ-glutamyltranspeptidase (GGT)-based fluorescent probe that we previously developed. Using 5-min ΔFI thresholds, positive, uncertain, and negative classifications were 24.1, 53.6, and 22.3%, respectively. At 20 min, these classifications improved to 28.1, 38.3, and 33.6%, respectively. At 5 and 20 min, positive predictive values were 93.9% and 94.8%, whereas negative predictive values were 95.1% and 96.7%, respectively. Compared with the GGT probe, α-Man substantially reduced the uncertain classification rate while maintaining high predictive accuracy. This study demonstrated that a two-step ΔFI-based protocol using the α-Man probe enables the accurate, real-time, and pathologist-independent assessment of resected specimens, supporting its future application to intraoperative margin evaluation during BCS.

Для цитирования: Ueo Hiroki, Ueo Hiroaki, Doi Takako, Yamaguchi Miki, Akashi-Tanaka Sadako, Takamaru Tomoko, Tsuda Hitoshi, Moriya Takuya, Yamaguchi Rin, Kozuka Yuji, Sasaki Takeshi, Gamachi Ayako, Kai Yuichiro, Kubota Yoko, Kunii Shun, Nagamori Yui, Fujita Kyohhei, Urano Yasuteru, Ando Yuki, Mimori Koshi, Masuda Takaaki. Multicenter ex vivo evaluation of an α-mannosidase-targeted fluorescent probe for intraoperative margin assessment in breast cancer.. Scientific reports. 2026. DOI: 10.1038/s41598-026-42316-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.