DOI 10.1111/j.1532-950x.2011.00893.x
Perpendicular pull-out force of locking versus non-locking plates in thin cortical bone using a canine mandibular ramus model.
Аннотация
OBJECTIVE
To compare the holding strength of a conventional plate-screw construct with a locking plate-screw construct in the thin cortical bone of the canine mandibular ramus.
STUDY
DESIGN
Mechanical study.
ANIMALS: Paired cadaveric canine mandibles (n = 10 pairs).
METHODS
Perpendicular pull-out testing was performed on 2.0-mm limited-contact dynamic compression plate (LC-DCP)-screw constructs and 2.0-mm string-of-pearls (SOP) plate-screw constructs applied to the ramus of the canine mandible. Pull-out force was applied perpendicular to the long axis of the plates. Construct stiffness and load at failure were determined from load-displacement curves and method of failure was determined from high speed digital video recordings. A paired t-test was used to compare mean construct stiffness and load at failure between groups.
RESULTS
SOP plate-screw constructs had a significantly higher mean construct stiffness and load at failure than did LC-DCP-screw constructs. LC-DCP constructs failed by screw pull-out while bone slicing and fracture were prominent mechanisms of failure for SOP constructs.
CONCLUSIONS
SOP plate-screw constructs sustained a significantly higher perpendicular load at failure than did LC-DCP-screw constructs.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.