DOI 10.1161/circulationaha.105.533513

Медицинская библиотека · Circulation · 2005

Incidence and clinical relevance of slow ventricular tachycardia in implantable cardioverter-defibrillator recipients: an international multicenter prospective study.

Sadoul Nicolas, Mletzko Ralph, Anselme Frédéric, Bowes Robert, Schöls Wolfgang, Kouakam Claude, Casteigneau Gaëlle, Luise Raffaele, Iscolo Nicolas, Aliot Etienne, Slow VT Study Group

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

This study aims to assess the incidence and clinical relevance of slow ventricular tachycardia (VT) and the effectiveness and/or deleterious effects of antitachycardia pacing in slow VT in implantable cardioverter-defibrillator recipients.

METHODS AND

RESULTS

This multicenter prospective randomized study included 374 patients (326 men) without prior history of slow VT (<148 bpm) implanted with a dual-chamber implantable cardioverter-defibrillator. Patients had a 3-zone detection configuration: a slow VT zone (101 to 148 bpm), a conventional VT zone (>148 bpm), and a ventricular fibrillation zone. Patients were randomized to a treatment group (n=183) with therapy activated in the slow VT zone or a monitoring group (n=191) with no therapy in the slow VT zone. During follow-up (11 months), 449 slow VTs occurred in 114 patients (30.5% slow VT incidence); 181 VTs (54 patients) occurred in the monitoring group; 3 were readmitted to the hospital; and lightheadedness and palpitations occurred in 4 and 250 (60 patients) in the treatment group treated by antitachycardia pacing (89.8% success rate) and shock delivery (n=2). There were 10 crossovers from the monitoring to treatment group and 3 crossovers from the treatment to monitoring group (P=0.09). Quality of life scores were not different between groups.

CONCLUSIONS

Slow VT incidence (<150 bpm) is high (30%) in implantable cardioverter-defibrillator recipients without prior history of slow VT, has limited clinical relevance, and is efficiently and safely terminated by antitachycardia pacing.

Для цитирования: Sadoul Nicolas, Mletzko Ralph, Anselme Frédéric, Bowes Robert, Schöls Wolfgang, Kouakam Claude, Casteigneau Gaëlle, Luise Raffaele, Iscolo Nicolas, Aliot Etienne, Slow VT Study Group. Incidence and clinical relevance of slow ventricular tachycardia in implantable cardioverter-defibrillator recipients: an international multicenter prospective study.. Circulation. 2005. DOI: 10.1161/circulationaha.105.533513.

Предметные рубрики MeSH