DOI 10.12998/wjcc.v9.i34.10733
Tracheal tube misplacement in the thoracic cavity: A case report.
Аннотация
BACKGROUND
Penetrating neck injuries require prompt recognition, diagnosis and management of critical airways. This case demonstrates an emergent situation that a "medical negligence" was avoided with the aid of end-tidal carbon dioxide (ETCO2) waveform.
CASE SUMMARY: We report a case of malposition of the endotracheal tube into the right hemithoracic cavity for cervical knife trauma, resulting in pneumothorax. Tube placement was not confirmed during emergency airway management, and the patient was directly transferred to the emergency operation room. Assisted by ETCO2 and imaging examinations, the anesthetist timely noticed the absence of ETCO2 waveform and resolved this urgent situation before anesthesia induction.
CONCLUSION
This case emphasizes the necessity of ETCO2 waveform and/or X-ray confirmation of endotracheal intubation even in emergent situations.