MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajem.2020.04.007

Медицинская библиотека · The American journal of emergency medicine · 2020

The standardized method and clinical experience may improve the reliability of visually assessed capillary refill time.

Shinozaki Koichiro, Jacobson Lee S, Saeki Kota, Kobayashi Naoki, Weisner Steve, Falotico Julianne M, Li Timmy, Kim Junhwan, Lampe Joshua W, Becker Lance B

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

Reliability of capillary refill time (CRT) has been questionable. The purpose of this study was to examine that a standardized method and clinical experience would improve the reliability of CRT.

METHODS

This was a cross-sectional study in the emergency department (ED). Health care providers (HCPs) performed CRT without instruments (method 1) to classify patients as having normal or abnormal (≤2/>2 s) CRT. An ED attending physician quantitatively measured CRT using a chronograph (standardized visual CRT, method 2). A video camera was mounted on top of the hand tool to obtain a digital recording. The videos were used to calculate CRT via image software (image CRT, method 3) as a criterion standard of methods. Additionally, 9 HCPs reviewed the videos in a separate setting in order to visually assess CRT (video CRT, method 4).

RESULTS

We enrolled 30 patients in this study. Standardized visual CRT (method 2) identified 10 abnormal patients, while two patients were identified by CRT without instruments (method 1). There was no correlation (κ value, 0.00) between CRT without instruments (method 1) and image CRT (method 3), however the correlation between standardized visual CRT (method 2) and image CRT (method 3) was strong (r = 0.64, p < 0.01). Both intra-observer reliability and correlation coefficient with image CRT (method 3) was higher in video CRT (method 4) by more experienced clinicians.

CONCLUSIONS

Visual assessment is variable but a standardized method such as using a chronograph and/or clinical experience may aid clinicians to improve the reliability of visually assessed CRT.

Для цитирования: Shinozaki Koichiro, Jacobson Lee S, Saeki Kota, Kobayashi Naoki, Weisner Steve, Falotico Julianne M, Li Timmy, Kim Junhwan, Lampe Joshua W, Becker Lance B. The standardized method and clinical experience may improve the reliability of visually assessed capillary refill time.. The American journal of emergency medicine. 2020. DOI: 10.1016/j.ajem.2020.04.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.