A novel method of calculating stroke volume using point-of-care echocardiography.

СтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Aligholizadeh Ehson, Teeter William, Patel Rajan, Hu Peter, Fatima Syeda, Yang Shiming, Ramani Gautam, Safadi Sami, Olivieri Peter, Scalea Thomas, Murthi Sarah

Аннотация

BACKGROUND: Point-of-care transthoracic echocardiography (POC-TTE) is essential in shock management, allowing for stroke volume (SV) and cardiac output (CO) estimation using left ventricular outflow tract diameter (LVOTD) and left ventricular velocity time integral (VTI). Since LVOTD is difficult to obtain and error-prone, the body surface area (BSA) or a modified BSA (mBSA) is sometimes used as a surrogate (LVOTDBSA, LVOTDmBSA). Currently, no models of LVOTD based on patient characteristics exist nor have BSA-based alternatives been validated.

METHODS: Focused rapid echocardiographic evaluations (FREEs) performed in intensive care unit patients over a 3-year period were reviewed. The age, sex, height, and weight were recorded. Human expert measurement of LVOTD (LVOTDHEM) was performed. An epsilon-support vector regression was used to derive a computer model of the predicted LVOTD (LVOTDCM). Training, testing, and validation were completed. Pearson coefficient and Bland-Altman were used to assess correlation and agreement.

RESULTS: Two hundred eighty-seven TTEs with ideal images of the LVOT were identified. LVOTDCM was the best method of SV measurement, with a correlation of 0.87. LVOTDmBSA and LVOTDBSA had correlations of 0.71 and 0.49 respectively. Root mean square error for LVOTDCM, LVOTDmBSA, and LVOTDBSA respectively were 13.3, 37.0, and 26.4. Bland-Altman for LVOTDCM demonstrated a bias of 5.2. LVOTDCM model was used in a separate validation set of 116 ideal images yielding a linear correlation of 0.83 between SVHEM and SVCM. Bland Altman analysis for SVCM had a bias of 2.3 with limits of agreement (LOAs) of - 24 and 29, a percent error (PE) of 34% and a root mean square error (RMSE) of 13.9.

CONCLUSIONS: A computer model may allow for SV and CO measurement when the LVOTD cannot be assessed. Further study is needed to assess the accuracy of the model in various patient populations and in comparison to the gold standard pulmonary artery catheter. The LVOTDCM is more accurate with less error compared to BSA-based methods, however there is still a percentage error of 33%. BSA should not be used as a surrogate measure of LVOTD. Once validated and improved this model may improve feasibility and allow hemodynamic monitoring via POC-TTE once it is validated.