MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Zhonghua kou qiang yi xue za zhi = Zhonghua kouqiang yixue zazhi = Chinese journal of stomatology · 2015

[Correlation analysis of hearing level and soft palate movement after palatoplasty].

Lou Qun, Ma Xiaoran, Ma Lian, Luo Yi, Zhu Hongping, Zhou Zhibo

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To explore the relationship between hearing level and soft palate movement after palatoplasty and to verify the importance of recovery of soft palate movement function for improving the middle ear function as well as reducing the hearing loss.

METHODS

A total of 64 non-syndromic cleft palate patients were selected and the lateral cephalometric radiographs were taken. The patients hearing level was evaluated by the pure tone hearing threshold examination. This study also analyzed the correlation between hearing threshold of the patients after palatoplasty and the soft palate elevation angle and velopharyngeal rate respectively.

RESULTS

Kendall correlation analysis revealed that the correlation coefficient between hearing threshold and the soft palate elevation angle after palatoplasty was -0.339 (r = -0.339, P < 0.01).The correlation showed a negative correlation. The hearing threshold decreased as the soft palate elevation angle increased. After palatoplasty, the correlation coefficient between the hearing threshold and the rate of velopharyngeal closure was -0.277 (r = -0.277, P < 0.01). The correlation showed a negative correlation. While, The hearing threshold decreased with the increase of velopharyngeal closure rate. The hearing threshold was correlated with soft palate elevation angle and velpharyngeal closure rate.

CONCLUSIONS

The movement of soft palate and velopharyngeal closure function after palatoplasty both have impact on patient hearing level. In terms of the influence level, the movement of soft palate has a higher level of impact on patient hearing level than velopharygeal closure function.

Для цитирования: Lou Qun, Ma Xiaoran, Ma Lian, Luo Yi, Zhu Hongping, Zhou Zhibo. [Correlation analysis of hearing level and soft palate movement after palatoplasty].. Zhonghua kou qiang yi xue za zhi = Zhonghua kouqiang yixue zazhi = Chinese journal of stomatology. 2015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.