Scaling up the spray drying process from pilot to production scale using an atomized droplet size criterion.

Thybo Pia, Hovgaard Lars, Lindeløv Jesper Saederup, Brask Anders, Andersen Sune Klint

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: The purpose of this study was to investigate the possibility of producing identical powders in pilot and production scale spray drying equipment by matching the droplet size distributions produced by two differently sized atomizers.

METHODS

Particles were prepared by spray drying solutions of acetaminophen and polyvinylpyrrolidone K-30. The success of the up-scaling was evaluated by comparing the powders in terms of particle size distribution (laser diffraction), crystallinity (XPRD) and morphology (SEM). Furthermore, the influence of process parameters on other product characteristics such as stability and residual volatile content was also evaluated.

RESULTS

The spray drying experiments resulted in spherical, amorphous particles with volumetric median diameters of typically 4-10 microm for pilot scale and 4-30 microm for production scale. The results showed that particles with similar morphology and crystallinity could be produced in the two applied spray dryers. However, scale-up based purely on matching droplet size distributions was not feasible.

CONCLUSIONS

The scale-up criterion did not account for the differences between the droplet-drying gas mixing and residence time distribution within the two spray dryers. Therefore, production scale experiments are required in order to obtain similar product characteristics as in pilot scale.

Для цитирования: Thybo Pia, Hovgaard Lars, Lindeløv Jesper Saederup, Brask Anders, Andersen Sune Klint. Scaling up the spray drying process from pilot to production scale using an atomized droplet size criterion.. Pharmaceutical research. 2008. DOI: 10.1007/s11095-008-9565-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.