Dosimetric effects of internal margin, auto flash, and virtual bolus in VMAT-based whole-breast radiotherapy under motion variations.

Joo Ji Hyeon, Kim Dong Woon, Kim Wontaek, Nam Jiho, Kim Donghyun, Park Dahl, Jung Youn Joo, Kim Hyun Yul, Choo Ki Seok, Nam Kyung Jin, Nam Su Bong, Kim Jae Joon, Ki Yongkan

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: This study aimed to evaluate the dosimetric performance and robustness of volumetric modulated arc therapy (VMAT) planning techniques-planning target volume with internal margin (INT), auto flash (AF), and virtual bolus (VB)-under simulated geometric changes during whole-breast radiotherapy.

METHODS

Nine patients with left-sided breast cancer were included. Three planning techniques were compared: INT with a 5-mm skin-sparing internal margin, AF with a 1-cm automatic skin flash margin, and VB with a 5-mm optimization bolus applied only during the planning. Respiratory motion was simulated by shifting the plan center (± 3 mm and ± 5 mm) and recalculating the dose distributions.

RESULTS

Under static conditions, all plans provided adequate target coverage, with planning target volume (PTV) V95% values of 96.45% (INT), 97.35% (AF), and 98.19% (VB). Under breast swelling of up to 5 mm, AF maintained the most stable coverage (PTV V95% = 99.10%), outperforming VB (95.02%) and INT (92.31%) (p < 0.001). In simulated incomplete inspiration (5 mm), VB showed superior robustness, achieving a PTV V95% of 90.46% compared with AF (85.30%) and INT (85.08%) (p = 0.008). AF met the ideal criteria in all cases under swelling conditions, whereas the VB was more effective against suboptimal respiration.

CONCLUSIONS

In VMAT breast radiation therapy (RT), the conventional INT approach was the least robust against variations, and additional techniques are required. AF effectively compensates for breast swelling, whereas VB preserves the target coverage under insufficient breath-hold conditions. Surface-guided radiation therapy (SGRT) and visual guidance are recommended to ensure accurate treatment.

Для цитирования: Joo Ji Hyeon, Kim Dong Woon, Kim Wontaek, Nam Jiho, Kim Donghyun, Park Dahl, Jung Youn Joo, Kim Hyun Yul, Choo Ki Seok, Nam Kyung Jin, Nam Su Bong, Kim Jae Joon, Ki Yongkan. Dosimetric effects of internal margin, auto flash, and virtual bolus in VMAT-based whole-breast radiotherapy under motion variations.. Journal of applied clinical medical physics. 2026. DOI: 10.1002/acm2.70471.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.