MedElevator Войти в исследования
← Поиск публикаций

DOI 10.17772/gp/2401

Медицинская библиотека · Ginekologia polska · 2015

Elastography for predicting preterm delivery in patients with short cervical length at 18-22 weeks of gestation: a prospective observational study.

Woźniak Sławomir, Czuczwar Piotr, Szkodziak Piotr, Wrona Wojciech, Paszkowski Tomasz

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

The aim of the study was to estimate the potential value of elastographic evaluation of the internal cervical os at 18-22 weeks of pregnancy in patients with short cervical length for prediction of preterm delivery (PTD).

MATERIAL AND

METHODS

This prospective observational study included 109 patients with cervical length of ≤ 25 mm at 18-22 weeks scan. Stiffness of the internal cervical os was assessed by elastography. Elastographic assessment of the internal os was performed using a color map: red (soft), yellow (medium soft), blue (medium hard), and purple (hard). If two colors were visible in the region of the internal os, the softer option was noted. The following outcome measures were analyzed: percentage of PTDs in various categories of elastographic cervical assessment, sensitivity specificity negative predictive value (NPV), and positive predictive value (PPV) of elastography in predicting PTDs. Additionally ROC curves were constructed for elastography and cervical length for predicting PTDs.

RESULTS

Forty-five cases of PTDs (< 37 weeks of pregnancy) were found in the studied population. The number of PTDs was significantly higher in the red group, than in the blue and purple groups. The sensitivity specificity NPV and PPV for the assessment of both, red and yellow internal os for predicting preterm delivery were 82.2%, 75.0%, 84.0% and 72.5% respectively The cut-off value for elastography suggested inclusion of both, red and yellow (warm) colors as predictors of PTD.

CONCLUSIONS

Elastographic evaluation of the internal cervical os at 18-22 weeks of pregnancy in patients with short cervical length may be useful in predicting PTD.

Для цитирования: Woźniak Sławomir, Czuczwar Piotr, Szkodziak Piotr, Wrona Wojciech, Paszkowski Tomasz. Elastography for predicting preterm delivery in patients with short cervical length at 18-22 weeks of gestation: a prospective observational study.. Ginekologia polska. 2015. DOI: 10.17772/gp/2401.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.