PURPOSE: To compare the relative competency of pars plana vitrectomy (PPV) sclerotomies.

DESIGN

Laboratory investigation.

METHODS

PPV was performed in human cadaveric eyes using 20-gauge (20 G), 23-gauge (23 G), and 25-gauge (25 G) instrumentation. India ink was applied over a sclerotomy site while the intraocular pressure was varied. The presence of India ink particles (IIPs) along incisions was evaluated by histologic analysis. Spectrophotometric absorbance levels of vitreous aspirates were measured.

RESULTS

PPV was performed in a control eye and two eyes, each using standard 20 G, standard 23 G, perpendicular 25 G, and beveled 25 G instrumentation incisions. IIPs were not detected in the 20 G incisions either on histology or by spectrophotometry. IIPs were detected along the entire incision length in one of two eyes with 23 G sclerotomies and confirmed by spectrophotometry. IIPs were detected along the entire incision length in one of two eyes with 25 G perpendicular sclerotomies and confirmed by spectrophotometry in both eyes. IIPs were noted partially along the length in one of the two beveled 25 G eyes, but not detected in either eye by spectrophotometry.

CONCLUSIONS

During the early postoperative period, sutureless vitrectomy incisions may allow entry of ocular surface fluid. These findings may provide a pathophysiologic mechanism for the reported increased risk of endophthalmitis in small-gauge vitrectomy surgery.

Для цитирования: Gupta Omesh P, Maguire Joseph I, Eagle Ralph C, Garg Sunir J, Gonye Gregory E. The competency of pars plana vitrectomy incisions: a comparative histologic and spectrophotometric analysis.. American journal of ophthalmology. 2008. DOI: 10.1016/j.ajo.2008.08.025.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.