MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtcvs.2020.01.090

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2020

Utility of neuromonitoring in hypothermic circulatory arrest cases for early detection of stroke: Listening through the noise.

Ghincea Christian V, Anderson Devon A, Ikeno Yuki, Roda Gavriel F, Eldeiry Mohamed, Bronsert Michael R, Aunkst Kelly, Fullerton David A, Reece T Brett, Aftab Muhammad

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Stroke remains a potentially devastating complication of aortic arch intervention. The value of neurophysiologic intraoperative monitoring (NIOM) in the early identification of stroke is unclear. We evaluated the utility of NIOM for early stroke detection in aortic arch surgery.

METHODS

Across 8 years at our institution, 365 patients underwent aortic arch surgery with hypothermic circulatory arrest, and 224 cases utilized NIOM. One patient was excluded for intraoperative death. In the remaining cohort, we reviewed the incidence, timing, and location of strokes, and the incidence and nature of NIOM alerts.

RESULTS

Hemiarch was performed in 154 patients and total arch replacement in 69 patients. Stroke occurred in 6.3% of all cases (14 out of 223), 15.9% of total arches (11 out of 69), and 2.0% of hemiarches (3 out of 154). There were 33 NIOM alerts (14.8%), and 9 patients had both alerts and stroke. Of these, NIOM deficits plausibly correlated with imaging findings in 7 cases (78%). Of the 5 stroke patients without NIOM alerts, 2 developed neurologic symptoms 3 days or more postoperatively, and infarcts in 3 patients did not result in sensory or motor deficits. Excluding 2 patients with late stroke, the sensitivity of NIOM for stroke detection was 75%, specificity was 88.5%, positive predictive value was 27.3%, and negative predictive value was 97.4%.

CONCLUSIONS

Despite a low positive predictive value requiring a high level of discrimination when interpreting abnormal findings, NIOM has high sensitivity and specificity for the early stroke detection. Furthermore, its high negative predictive valve is reassuring for low risk of stroke in the absence of alerts.

Для цитирования: Ghincea Christian V, Anderson Devon A, Ikeno Yuki, Roda Gavriel F, Eldeiry Mohamed, Bronsert Michael R, Aunkst Kelly, Fullerton David A, Reece T Brett, Aftab Muhammad. Utility of neuromonitoring in hypothermic circulatory arrest cases for early detection of stroke: Listening through the noise.. The Journal of thoracic and cardiovascular surgery. 2020. DOI: 10.1016/j.jtcvs.2020.01.090.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.