MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcard.2020.08.089

Медицинская библиотека · International journal of cardiology · 2020

Comparison of transvenous vs subcutaneous defibrillator therapy in patients with cardiac arrhythmia syndromes and genetic cardiomyopathies.

Kuschyk Jürgen, Müller-Leisse Johanna, Duncker David, Tülümen Erol, Fastenrath Fabian, Fastner Christian, Kruska Mathieu, Akin Ibrahim, Liebe Volker, Borggrefe Martin, Veltmann Christian, Rudic Boris

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Inherited arrhythmia syndromes and genetic cardiomyopathies attribute in a significant proportion to sudden cardiac death. Implantable cardioverter defibrillators (ICDs) are the cornerstone in the prevention of sudden death in high-risk patients. However, ICD therapy is also associated with high rates of inappropriate shocks and/or device-related complications especially in young patients.

OBJECTIVE

To determine the outcome of high-risk patients with inherited arrhythmia syndromes and genetic cardiomyopathies comparing two defibrillator technologies.

METHOD: Between 2010 and 2018, 183 consecutive patients from two large German tertiary care centers were enrolled in the study. The majority of patients (83%) had either cardiac channelopathies or idiopathic ventricular fibrillation without cardiac structural abnormalities, while the remaining 17% had a genetic cardiomyopathy (HCM/ARVC). Eighty-six patients (47%) received a transvenous ICD (TV-ICD), while a subcutaneous ICD (S-ICD) was implanted in another 97 patients (53%).

RESULTS

During a mean follow-up of 4.3 years, 30 patients had an appropriate ICD therapy (annual rate 3.8%). Fifteen patients experienced an inappropriate shock (annual rate 1.9%). Lead failure occurred in 17 (9%) patients and was less frequent in the S-ICD group (OR 0.48, 95%CI 0.38-0.62). Adverse defibrillator events, defined as a composite of inappropriate shocks and lead failure requiring surgical revision were significantly lower in the S-ICD group as compared to the TV-ICD group (OR 0.55, 95%CI 0.41-0.72). There was a non-significant trend towards lower appropriate shocks in the S-ICD group, that in combination with all-cause shocks yielded in a significantly higher freedom of any shock in the S-ICD group (RR 39%, p = 0.003). No deaths occurred during follow-up.

CONCLUSION

The present data favor the use of the subcutaneous ICD for patients with inherited arrhythmia syndromes and genetic cardiomyopathies who do not need anti-bradycardia pacing.

Для цитирования: Kuschyk Jürgen, Müller-Leisse Johanna, Duncker David, Tülümen Erol, Fastenrath Fabian, Fastner Christian, Kruska Mathieu, Akin Ibrahim, Liebe Volker, Borggrefe Martin, Veltmann Christian, Rudic Boris. Comparison of transvenous vs subcutaneous defibrillator therapy in patients with cardiac arrhythmia syndromes and genetic cardiomyopathies.. International journal of cardiology. 2020. DOI: 10.1016/j.ijcard.2020.08.089.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.