MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajo.2008.07.046

Медицинская библиотека · American journal of ophthalmology · 2008

Evaluation of wound closure in oblique 23-gauge sutureless sclerotomies with visante optical coherence tomography.

Taban Mehran, Sharma Sumit, Ventura Alexandre A C M, Kaiser Peter K

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: To investigate the in vivo real-time wound morphology of fresh 23-gauge sutureless oblique sclerotomy wounds with anterior segment optical coherence tomography (OCT).

DESIGN

Prospective, observational case series.

METHODS

Subjects underwent three-port pars plana vitrectomy with a 23-gauge trocar/cannula microincision surgical system at the Cole Eye Institute. All incisions were created in an oblique (aka beveled or angled) fashion. The incisions were imaged with the Visante OCT (Carl Zeiss Meditec, Dublin, California, USA) device on postoperative days 1 and 8. The main outcome measure was wound structure (eg, presence of gaping) as evaluated with OCT. Surgical and ocular parameters were also recorded.

RESULTS

Fourteen patients were investigated. Gross clinical examination revealed no evidence of leakage. OCT demonstrated closed wounds in all eyes on postoperative days 1 and 8. The external (entry) site of the incision was occasionally seen as a gape; however the rest of the wound was closed. One patient with closed wounds had transient hypotony along with shallow peripheral choroidals noted on postoperative day 1, which resolved on their own.

CONCLUSIONS

Oblique incisions have been proposed for microincision sutureless vitrectomy to prevent wound leakage, hypotony, and the secondary risk of endophthalmitis. This study demonstrates that oblique incisions provide adequate wound apposition as shown by OCT even on postoperative day 1.

Для цитирования: Taban Mehran, Sharma Sumit, Ventura Alexandre A C M, Kaiser Peter K. Evaluation of wound closure in oblique 23-gauge sutureless sclerotomies with visante optical coherence tomography.. American journal of ophthalmology. 2008. DOI: 10.1016/j.ajo.2008.07.046.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.