What is known in pre-, peri-, and post-procedural anticoagulation in micro-axial flow pump protected percutaneous coronary intervention?

Leick Jürgen, Grottke Oliver, Oezkur Mehmet, Mangner Norman, Sanna Tommaso, Al Rashid Fadi, Vandenbriele Christophe

СтатьяПеревод в очереди

Аннотация

Interest in the use of percutaneous left ventricular assist devices (p-LVADs) for patients undergoing high-risk percutaneous coronary intervention (PCI) is growing rapidly. The Impella™ (Abiomed Inc.) is a catheter-based continuous micro-axial flow pump that preserves haemodynamic support during high-risk PCI. Anticoagulation is required to counteract the activation of the coagulation system by the patient's procoagulant state and the foreign-body surface of the pump. Excessive anticoagulation and the effect of dual antiplatelet therapy (DAPT) increase the risk of bleeding. Inadequate anticoagulation leads to thrombus formation and device dysfunction. The precarious balance between bleeding and thrombosis in patients with p-LVAD support is often the primary reason that patients' outcomes are jeopardized. In this chapter, we will discuss anticoagulation strategies and anticoagulant management in the setting of protected PCI. This includes anticoagulant therapy with unfractionated heparin, direct thrombin inhibitors, DAPT, purge blockage prevention by bicarbonate-based purge solution, and monitoring by activated clotting time, partial thromboplastin time, as well as anti-factor Xa levels. Here, we provide a standardized approach to the management of peri-interventional anticoagulation in patients undergoing protected PCI.

Для цитирования: Leick Jürgen, Grottke Oliver, Oezkur Mehmet, Mangner Norman, Sanna Tommaso, Al Rashid Fadi, Vandenbriele Christophe. What is known in pre-, peri-, and post-procedural anticoagulation in micro-axial flow pump protected percutaneous coronary intervention?. European heart journal supplements : journal of the European Society of Cardiology. 2022. DOI: 10.1093/eurheartjsupp/suac066.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.