MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2023.11.028

Медицинская библиотека · Heart rhythm · 2023

Detecting deceased patients on cardiac device remote monitoring: A case series and management guide for cardiac device services.

Monkhouse Christopher, Elliott James, Whittaker-Axon Sarah, Collinson Jason, Chow Anthony, Moore Philip, Muthumala Amal, Honarbakhsh Shohreh, Hunter Ross, Lambiase Pier, Ahsan Syed, Sporton Simon

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Remote monitoring (RM) of implantable cardiac devices provides substantial and complex information, presenting new challenges such as detection of a patient's death.

OBJECTIVE

This study aims to describe RM transmissions indicating death and propose a management strategy for services.

METHODS

The study included consecutive ambulatory outpatients whose deaths were detected via RM. Clinical and device data were collected from electronic records, and ethical approval was obtained from the service's institutional review board.

RESULTS

Over a 9-year period (2014-2023), 28 patients were detected. The deceased patients had implantable cardioverter-defibrillators, pacemakers, and implantable loop recorders. In 54% of the cases, the patient's death had already been recognized. Alert transmissions indicating death were commonly related to ventricular arrhythmia events, but also due to lead measurements, and implantable loop recorder battery status. Several diagnostic features may indicate a patient's death. The most reliable was the presenting electrogram, demonstrating base rate pacing with no capture. Device diagnostics, lead parameters, and arrhythmia recordings may indicate death; however, not all cases present with recordings and diagnosis may not be conclusive. A majority (82%) had ventricular arrhythmia at the time of death. In cases where defibrillator shocks were delivered, the arrhythmia reinitiated shortly after successful cardioversion. Delayed therapy was observed, and some patients did not receive defibrillator shocks because of discriminators or because the arrhythmia rate fell below the shock zone.

CONCLUSION

Detecting a patient death via RM presents unique challenges and considerations for services. Standard operational policies and legal consultation should be established to address the implications.

Для цитирования: Monkhouse Christopher, Elliott James, Whittaker-Axon Sarah, Collinson Jason, Chow Anthony, Moore Philip, Muthumala Amal, Honarbakhsh Shohreh, Hunter Ross, Lambiase Pier, Ahsan Syed, Sporton Simon. Detecting deceased patients on cardiac device remote monitoring: A case series and management guide for cardiac device services.. Heart rhythm. 2023. DOI: 10.1016/j.hrthm.2023.11.028.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.