MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cca.2022.12.011

Медицинская библиотека · Clinica chimica acta; international journal of clinical chemistry · 2022

Newborn screening for Cerebrotendinous Xanthomatosis: A retrospective biomarker study using both flow-injection and UPLC-MS/MS analysis in 20,000 newborns.

Vaz Frédéric M, Jamal Youssra, Barto Rob, Gelb Michael H, DeBarber Andrea E, Wevers Ron A, Nelen Marcel R, Verrips Aad, Bootsma Albert H, Bouva Marelle J, Kleise Nick, van der Zee Walter, He Tao, Salomons Gajja S, Huidekoper Hidde H

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND AIMS: Cerebrotendinous Xanthomatosis (CTX) is a treatable disorder of bile acid synthesis caused by deficiency of 27-sterol hydroxylase -encoded by CYP27A1- leading to gastrointestinal and progressive neuropsychiatric symptoms. Biochemically, CTX is characterized by accumulation of the bile alcohol cholestanetetrol glucuronide (GlcA-tetrol) and the deficiency of tauro-chenodeoxycholic acid (t-CDCA) and tauro-trihydroxycholestanoic acid (t-THCA).

MATERIALS AND

METHODS

To ascertain the feasibility of CTX newborn screening (NBS) we performed a study with deidentified Dutch dried blood spots using reagents and equipment that is frequently used in NBS laboratories. 20,076 deidentified newborn blood spots were subjected to flow-injection (FIA)-MS/MS and UPLC-MS/MS analysis to determine the concentration of GlcA-tetrol and calculate the GlcA-tetrol/t-CDCA and t-THCA/GlcA-tetrol ratios.

RESULTS

Using UPLC-MS/MS analysis both GlcA-tetrol concentration and/or metabolite ratios GlcA-tetrol/t-CDCA proved to be informative biomarkers; newborn DBS results did not overlap with those of the CTX patients. For FIA-MS/MS, GlcA-tetrol also was an excellent marker but when using the combination of the GlcA-tetrol/t-CDCA and t-THCA/GlcA-tetrol ratios also did not yield any screen positives.

CONCLUSION

Newborn screening for CTX using only metabolite ratios following the measurement of three CTX biomarkers is possible using either FIA-MS/MS or UPLC-MS/MS, which paves the way for introduction of CTX NBS.

Для цитирования: Vaz Frédéric M, Jamal Youssra, Barto Rob, Gelb Michael H, DeBarber Andrea E, Wevers Ron A, Nelen Marcel R, Verrips Aad, Bootsma Albert H, Bouva Marelle J, Kleise Nick, van der Zee Walter, He Tao, Salomons Gajja S, Huidekoper Hidde H. Newborn screening for Cerebrotendinous Xanthomatosis: A retrospective biomarker study using both flow-injection and UPLC-MS/MS analysis in 20,000 newborns.. Clinica chimica acta; international journal of clinical chemistry. 2022. DOI: 10.1016/j.cca.2022.12.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.