Transfusion-related adverse reactions reported to the National Healthcare Safety Network Hemovigilance Module, United States, 2010 to 2012.

Harvey Alexis R, Basavaraju Sridhar V, Chung Koo-Whang, Kuehnert Matthew J

СтатьяПеревод в очереди

Аннотация

BACKGROUND

In 2010, health care facilities in the United States began voluntary enrollment in the National Healthcare Safety Network (NHSN) Hemovigilance Module. Participants report transfusion practices; red blood cell, platelet (PLT), plasma, and cryoprecipitate units transfused; and transfusion-related adverse reactions and process errors to the Centers for Disease Control and Prevention through a secure, Internet-accessible surveillance application available to transfusing facilities.

STUDY DESIGN AND

METHODS

Facilities submitting at least 1 month of transfused components data and adverse reactions from January 1, 2010, to December 31, 2012, were included in this analysis. Adverse reaction rates for transfused components, stratified by component type and collection and modification methods, were calculated.

RESULTS

In 2010 to 2012, a total of 77 facilities reported 5136 adverse reactions among 2,144,723 components transfused (239.5/100,000). Allergic (46.8%) and febrile nonhemolytic (36.1%) reactions were most frequent; 7.2% of all reactions were severe or life-threatening and 0.1% were fatal. PLT transfusions (421.7/100,000) had the highest adverse reaction rate.

CONCLUSION

Adverse transfusion reaction rates from the NHSN Hemovigilance Module in the United States are comparable to early hemovigilance reporting from other countries. Although severe reactions are infrequent, the numbers of transfusion reactions in US hospitals suggest that interventions to prevent these reactions are important for patient safety. Further investigation is needed to understand the apparent increased risk of reactions from apheresis-derived blood components. Comprehensive evaluation, including data validation, is important to continued refinement of the module.

Для цитирования: Harvey Alexis R, Basavaraju Sridhar V, Chung Koo-Whang, Kuehnert Matthew J. Transfusion-related adverse reactions reported to the National Healthcare Safety Network Hemovigilance Module, United States, 2010 to 2012.. Transfusion. 2014. DOI: 10.1111/trf.12918.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.