m+Medelevator.RU
← Поиск публикаций
European journal of nuclear medicine and molecular imaging · 2008

99mTc sestamibi myocardial perfusion scintigraphy with the novel use of metamizol for the detection of perfusion reversibility.

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ergün Eser Lay, Caglar Meltem, Bozkurt Murat Fani, Ergün Hakan

Аннотация

PURPOSE: This study aims to investigate whether induction with metamizol, an analgesic-antipyretic drug having spasmolitic activity, could be used to increase the detectability of ischemic/jeopardized myocardium during MPS (myocardial perfusion scintigraphy).

MATERIALS AND METHODS: Metamizol-enhanced rest MPS (45 min after administration of 1 g metamizol orally, 740 MBq (99m)Tc sestamibi was injected, MPS was acquired 45 min later) was performed in 21 patients who had perfusion defects on their previous stress-rest (99m)Tc sestamibi MPS. Blood pressure was monitored at 15-min intervals. Stress, rest, metamizol-rest MPS images were interpreted on the model of 20 segments using a visual uptake score (VUS; 0 = normal, 1 = mild, 2 = moderate, 3 = significant decreases, 4 = no uptake). (99m)Tc sestamibi uptake ratios (MIBI-UR; mean counts in the region of the perfusion defect/mean counts in the region of the normal-perfused wall) were obtained on each MPS and compared with each other. Average MIBI-UR in each scintigraphic examination was calculated. MPS were compared with coronary angiography results.

RESULTS: VUS and MIBI-UR results showed that metamizol-rest MPS displayed the defect reversibility better than rest MPS. Of the 14 segments with fixed perfusion defects on stress-rest MPS, 8 showed improvement of perfusion after metamizol induction. In 33 segments, lesion reversibility was better delineated on metamizol-rest MPS. Metamizol-induced sestamibi uptake was significantly higher (p < 0.001) than stress/baseline rest examinations as calculated by the MIBI-UR. Blood pressure remained unaltered. Coronary angiography results were in concordance with metamizol induced MPS.

CONCLUSIONS: Metamizol-enhanced rest MPS increases detectability of ischemic/viable myocardium during MPS. Metamizol should be discontinued like nitrates before stress MPS since it may mask the visualization of ischemic perfusion defects.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты