MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0015-0282(16)54471-9

Медицинская библиотека · Fertility and sterility · 1991

Fallopian tube catheterization and recanalization under ultrasonic observation: a simplified technique to evaluate tubal patency and open proximally obstructed tubes.

Lisse K, Sydow P

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To test a sonoscopic technique developed for transvaginal catheterization and recanalization of the fallopian tube.

DESIGN

In a feasibility study, catheterization was performed with the use of laparoscopic control. Patients with bilateral proximal tubal obstruction underwent fallopian tube recanalization under ultrasonic observation.

SETTING

This study represents patients evaluated for primary or secondary infertility at Humboldt University Hospital.

PATIENTS,

PARTICIPANTS

Proximal tubal obstruction had been diagnosed on previous hysterosalpingogram and with laparoscopy.

INTERVENTIONS: None.

MAIN OUTCOME MEASURE: Tubal patency was assessed by hydrotubation under ultrasonic observation.

RESULTS

Transvaginal catheterization was successful in 31 (91.2%) of the 34 tubes. In 19 patients with proximal tubal obstruction, patency of both or at least one tube was achieved in 16 (84.2%) women. Five (31.6%) of 16 patients successfully recanalized were found to have an intrauterine pregnancy at a 6-month follow-up interval.

CONCLUSION

This catheterization technique should be investigated for possible use in diagnostic schedule early in the evaluation of the infertile patient. Also, the transvaginal recanalization of proximally obstructed tubes calls into question the application of microsurgical treatment of a selected group of patients.

Для цитирования: Lisse K, Sydow P. Fallopian tube catheterization and recanalization under ultrasonic observation: a simplified technique to evaluate tubal patency and open proximally obstructed tubes.. Fertility and sterility. 1991. DOI: 10.1016/s0015-0282(16)54471-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.