MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acsomega.1c01814

Медицинская библиотека · ACS omega · 2021

Fully Automated Screening of a Combinatorial Library to Avoid False Positives: Application to Tetanus Toxoid Ligand Identification.

Martínez Ceron María C, Ávila Lucía, Giudicessi Silvana L, Minoia Juan M, Fingermann Matías, Camperi Silvia A, Albericio Fernando, Cascone Osvaldo

СтатьяПеревод в очереди

Аннотация

Peptide ligands are widely used in protein purification by affinity chromatography. Here, we applied a fully automated two-stage library screening method that avoids false positive peptidyl-bead selection and applied it to tetanus toxoid purification. The first library screening was performed using only sulforhodamine (a fluorescent dye), and fluorescent beads were isolated automatically by flow cytometry and discarded. A second screening was then performed with the rest of the library, using the target protein (tetanus toxoid)-rhodamine conjugate. This time, fluorescent beads were isolated, and peptide sequences were identified by matrix-assisted laser desorption/ionization tandem mass spectrometry. Those appearing with greater frequency were synthesized and immobilized on agarose to evaluate a range of chromatographic purification conditions. The affinity matrix PTx1-agarose (Ac-Leu-Arg-Val-Tyr-His-Gly-Gly-Ala-Gly-Lys-agarose) showed the best performance when 20 mM sodium phosphate, 0.05% Tween 20, pH 5.9 as adsorption buffer and 100 mM Tris-HCl, 100 mM NaCl, pH 8.0 as elution buffer were used. A pure tetanus toxoid (Ttx) was loaded on a chromatographic column filled with the PTx1 matrix, and 96% adsorption was achieved, with a K d of 9.18 ± 0.07 nmol/L and a q m of 1.31 ± 0.029 μmol Ttx/mL matrix. Next, a Clostridium tetani culture supernatant treated with formaldehyde (to obtain the toxoid) was applied as a sample. The sodium dodecyl sulfate polyacrylamide gel electrophoresis analysis showed a band, identified by electrospray ionization mass spectrometry as the Ttx, that appeared only in the elution fraction, where an S-layer protein was also detected.

Для цитирования: Martínez Ceron María C, Ávila Lucía, Giudicessi Silvana L, Minoia Juan M, Fingermann Matías, Camperi Silvia A, Albericio Fernando, Cascone Osvaldo. Fully Automated Screening of a Combinatorial Library to Avoid False Positives: Application to Tetanus Toxoid Ligand Identification.. ACS omega. 2021. DOI: 10.1021/acsomega.1c01814.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.