MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/eurheartj/ehl033

Медицинская библиотека · European heart journal · 2006

Long-term follow-up of homograft function after pulmonary valve replacement in patients with tetralogy of Fallot.

Oosterhof Thomas, Meijboom Folkert J, Vliegen Hubert W, Hazekamp Mark G, Zwinderman Aeiko H, Bouma Berto J, van Dijk Arie P J, Mulder Barbara J M

СтатьяПеревод в очереди

Аннотация

AIMS: To analyse the long-term outcomes after pulmonary valve replacement (PVR) in patients with a previous correction for tetralogy of Fallot.

METHODS AND

RESULTS

In a retrospective study, 158 adult patients with a diagnosis of tetralogy of Fallot, who had undergone a PVR after initial total correction in childhood, were identified from the CONCOR (CONgenital CORvitia) registry. All patients underwent 175 PVRs between June 1986 and June 2005. To analyse the predictors for homograft dysfunction and adverse events (death, reoperations, balloon angioplasty), Cox-regression analysis was performed. Overall freedom from significant homograft dysfunction was 66% after 5 years and 47% after 10 years. We could not identify predictors for combined homograft dysfunction. Event-free survival was 78% at 10 years and 68% at 15 years after PVR. Both early significant pulmonary regurgitation (PR) (HR 6.8, P = 0.017) and pulmonary stenosis (PS) (HR 4.0, P = 0.037) after surgery were associated with adverse events. When analysing direct post-operative PR or PS, we observed that in patients with severe, pre-operative PR, right ventricular aneurysm/patch resection resulted in a lower post-operative PR (mean difference grade 0.38 +/- 0.14, P = 0.01). Less significant post-operative PS was associated with a higher diameter of the homograft (HR 0.37, P = 0.006).

CONCLUSION

While 47% of the patients in our study were free from homograft dysfunction at 10 years after PVR, event-free survival after PVR remained fairly good (78%). Significant residual lesions directly after surgery influenced event-free survival. A smaller diameter of the pulmonary homograft and severe pre-surgical PR were related to early homograft dysfunction after surgery.

Для цитирования: Oosterhof Thomas, Meijboom Folkert J, Vliegen Hubert W, Hazekamp Mark G, Zwinderman Aeiko H, Bouma Berto J, van Dijk Arie P J, Mulder Barbara J M. Long-term follow-up of homograft function after pulmonary valve replacement in patients with tetralogy of Fallot.. European heart journal. 2006. DOI: 10.1093/eurheartj/ehl033.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.