BACKGROUND

The widespread use of transesophageal echocardiography (TEE) is limited by disadvantages, including patient intolerance and increased medical costs. We aimed to investigate the feasibility and safety of transnasal TEE in the detection of possible embolic sources in patients with atrial fibrillation (AF) and/or stroke, using an ultrathin TEE probe.

METHODS

Sixty-two patients with AF and/or stroke underwent transnasal TEE without conscious sedation. The presence or the absence of the following parameters was evaluated: left atrial (LA) thrombus; LA spontaneous echocardiographic contrast; intraatrial shunts; and aortic plaque.

RESULTS

The insertion of a TEE probe was successful in 52 (84%) patients. TEE found LA thrombus in 10 (19%) patients and other embolic sources in 4 (8%) patients. Two (4%) patients had mild epistaxis.

CONCLUSIONS

This study demonstrated that the use of transnasal TEE was feasible and safe in the detection of LA thrombus in patients with AF and/or stroke.

Для цитирования: Fukuda Shota, Shimada Kenei, Kawasaki Toshihiro, Taguchi Haruyuki, Maeda Kumiko, Fujimoto Hiromi, Inanami Hitoshi, Yoshida Ken, Jissho Satoshi, Yoshiyama Minoru, Yoshikawa Junichi. Transnasal transesophageal echocardiography in the detection of left atrial thrombus.. Journal of cardiology. 2009. DOI: 10.1016/j.jjcc.2009.07.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.