OBJECTIVE

The aim of this study was to describe a quantitative evaluation by real-time 3-dimensional (3D) echocardiography (RT-3DE) of atrial septal defect (ASD) and atrial septum that is important for patient selection for transcatheter closure, and to assess the reliability of RT-3DE findings compared with operation.

METHODS

Forty-five patients, who were scheduled for surgical or transcatheter closure of an ASD, were included in the study.

RESULTS

In 43 patients (96%), 3D reconstructions allowed optimal imaging of the ASD. The correlations between the ASD maximal diameter by RT-3DE and operation or balloon sizing were excellent (r > 0.95). All surrounding rims of the atrial septum could be assessed on 3D reconstruction; except for the aortic rim, a cross-sectional reconstruction was created mimicking the transesophageal echocardiographic cross section (r > 0.92).

CONCLUSION

RT-3DE allows accurate determination of ASD location, ASD size, and surrounding tissue of the atrial septum, and might replace transesophageal echocardiography for patient selection for surgical or transcatheter closure.

Для цитирования: van den Bosch Annemien E, Ten Harkel Derk-Jan, McGhie Jackie S, Roos-Hesselink Jolien W, Simoons Maarten L, Bogers Ad J J C, Meijboom Folkert J. Characterization of atrial septal defect assessed by real-time 3-dimensional echocardiography.. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. 2006. DOI: 10.1016/j.echo.2006.01.016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.