MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jss.2018.03.016

Медицинская библиотека · The Journal of surgical research · 2018

Buprenorphine-Sustained Release Alters Hemodynamic Parameters in a Rat Burn Model.

Guillory Ashley N, Clayton Robert P, Prasai Anesh, Jay Jayson W, Wetzel Michael, El Ayadi Amina, Herndon David N, Finnerty Celeste C

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

BACKGROUND

It has been previously shown that anesthesia and analgesia can affect outcomes in the rat burn model and that buprenorphine alleviated pain without drastically altering the outcomes of interest. Recently, the use of a sustained release (SR) formulation of buprenorphine has been promoted over conventional buprenorphine. In this study, we assessed whether buprenorphine-SR altered hemodynamic parameters in our rat model of severe burn injury.

MATERIALS AND

METHODS

Adult male Sprague-Dawley rats were randomized to receive either conventional buprenorphine (0.05 mg/kg) or buprenorphine-SR (1 mg/kg). Buprenorphine-SR was administered 24 h before the experiment. Buprenorphine was administered on the day of experiment. These groups were further randomized to control or scald burn (60% of total body surface area). Systolic and diastolic blood pressure (SBP, DBP) and heart rate (HR) were measured using a noninvasive blood pressure system before receiving analgesia and after 72 h.

RESULTS

As expected, HR was significantly higher after burn injury regardless of analgesic (P <0.0001). Both SBP and DBP were significantly decreased in burned animals receiving conventional buprenorphine (P < 0.0001), but neither was altered in the buprenorphine-SR-treated burned animals. However, SBP, DBP, and HR were significantly increased after 72 h in control animals receiving buprenorphine-SR (P < 0.0001).

CONCLUSIONS

These data indicate that buprenorphine-SR alters the hemodynamic response to injury and may not be an appropriate choice for a model of severe burn injury. If this analgesic is used, investigators must cautiously form conclusions, especially in experimental conditions that would be expected to alter cardiac hemodynamics.

Для цитирования: Guillory Ashley N, Clayton Robert P, Prasai Anesh, Jay Jayson W, Wetzel Michael, El Ayadi Amina, Herndon David N, Finnerty Celeste C. Buprenorphine-Sustained Release Alters Hemodynamic Parameters in a Rat Burn Model.. The Journal of surgical research. 2018. DOI: 10.1016/j.jss.2018.03.016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…