European journal of neurology · 2022
Valproate in status epilepticus: Correlation between loading dose, serum levels, and clinical response.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Vijiala Sergiu, André Pascal, Buclin Thierry, Decosterd Laurent A, Rossetti Andrea O, Novy Jan
Аннотация
BACKGROUND AND PURPOSE: Intravenous valproate (VPA) is an established treatment of status epilepticus (SE), but optimal loading dose was not fully assessed. We aimed at analyzing the correlation between VPA loading dose and subsequent plasma levels with clinical response in SE.
METHODS: This was a retrospective study in one referral center of all consecutive VPA-naïve SE episodes treated with VPA between January 2013 and June 2019, in which total VPA trough plasma levels after intravenous loading dose were available. Response to VPA, defined as last antiseizure medication introduced before SE resolution (without the need for additional treatment), was correlated with VPA loading dose and trough level. Correlations were adjusted for other SE characteristics.
RESULTS: Among 128 SE episodes, 53 (41%) responded to VPA. Median VPA loading dose was 25.2 mg/kg (range, 7-58 mg/kg). Loading doses and total plasma levels were not associated with the probability of response or mortality. Correcting for other possible confounders (number of previously tried treatment, demographics, SE severity) did not alter these findings. Only 3.8% of SE episodes that responded to VPA received >30 mg/kg.
CONCLUSIONS: A high loading dose (>30 mg/kg) is not associated with a greater response rate in patients with SE. Therefore, it seems to bring little benefit. If confirmed in further studies, a dosage of 25-30 mg/kg appears adequate in SE.
METHODS: This was a retrospective study in one referral center of all consecutive VPA-naïve SE episodes treated with VPA between January 2013 and June 2019, in which total VPA trough plasma levels after intravenous loading dose were available. Response to VPA, defined as last antiseizure medication introduced before SE resolution (without the need for additional treatment), was correlated with VPA loading dose and trough level. Correlations were adjusted for other SE characteristics.
RESULTS: Among 128 SE episodes, 53 (41%) responded to VPA. Median VPA loading dose was 25.2 mg/kg (range, 7-58 mg/kg). Loading doses and total plasma levels were not associated with the probability of response or mortality. Correcting for other possible confounders (number of previously tried treatment, demographics, SE severity) did not alter these findings. Only 3.8% of SE episodes that responded to VPA received >30 mg/kg.
CONCLUSIONS: A high loading dose (>30 mg/kg) is not associated with a greater response rate in patients with SE. Therefore, it seems to bring little benefit. If confirmed in further studies, a dosage of 25-30 mg/kg appears adequate in SE.