MedElevator Войти в исследования
← Поиск публикаций

DOI 10.17219/dmp/133894

Медицинская библиотека · Dental and medical problems · 2021

Effect of dental implant angulation on the dimensional accuracy of master casts.

Barjini Negar, Sayahpour Sahar, Jafari Maryam

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Making accurate impressions of dental implants and transferring their three-dimensional (3D) position to master casts is critical for the passive fit of prosthetic frameworks.

OBJECTIVES

This study aimed to assess the effect of dental implant angulation on the dimensional accuracy of master casts.

MATERIAL AND

METHODS

An acrylic model with 2 external hexagonal implants was used in this in vitro experimental study. The impressions of the model were made in 42 positions, with different angulation of the 2 implants, ranging from +15° to -15°, by means of the open-tray and closed-tray impression techniques, using a polyvinyl siloxane impression material. The spatial coordinates of the implants were measured on the X, Y and Z axes. The dimensional accuracy of the impressions made at different positions (parallel, convergent and divergent) and different angulation of the implants were determined. The data was analyzed using the one-way analysis of variance (ANOVA), Student's t test and Tukey's test.

RESULTS

Casts with the lowest accuracy were obtained when the 2 implants were divergent by 25° (R = 1.1336). However, the position of the 2 implants had no significant effect on the dimensional accuracy of the master casts. The error rate was 0.4181 in the open-tray technique and 0.5095 in the closed-tray technique, with no significant difference between them (p > 0.05). The angulation of the 2 implants had a significant effect on the dimensional accuracy of the master casts (p = 0.0001).

CONCLUSIONS

Considering the significant effect of implant angulation in the range from +15° to -15° relative to the longitudinal axis on the dimensional accuracy of master casts, further studies are required to reach a final conclusion in this respect.

Для цитирования: Barjini Negar, Sayahpour Sahar, Jafari Maryam. Effect of dental implant angulation on the dimensional accuracy of master casts.. Dental and medical problems. 2021. DOI: 10.17219/dmp/133894.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.