MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/shk.0000000000002345

Медицинская библиотека · Shock (Augusta, Ga.) · 2024

MAN VERSUS MACHINE: PROVIDER DIRECTED VERSUS PRECISION AUTOMATED CRITICAL CARE MANAGEMENT IN A PORCINE MODEL OF DISTRIBUTIVE SHOCK.

Sanin Gloria D, Cambronero Gabriel E, Wood Elizabeth C, Patterson James W, Lane Magan R, Renaldo Antonio C, Laingen Bonnie E, Rahbar Elaheh, Adams Jason Y, Johnson Austin, Neff Lucas P, Williams Timothy K

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Background

Critical care management of shock is a labor-intensive process. Precision Automated Critical Care Management (PACC-MAN) is an automated closed-loop system incorporating physiologic and hemodynamic inputs to deliver interventions while avoiding excessive fluid or vasopressor administration. To understand PACC-MAN efficacy, we compared PACC-MAN to provider-directed management (PDM). We hypothesized that PACC-MAN would achieve equivalent resuscitation outcomes to PDM while maintaining normotension with lower fluid and vasopressor requirements.

Methods

Twelve swine underwent 30% controlled hemorrhage over 30 min, followed by 45 min of aortic occlusion to generate a vasoplegic shock state, transfusion to euvolemia, and randomization to PACC-MAN or PDM for 4.25 h. Primary outcomes were total crystalloid volume, vasopressor administration, total time spent at hypotension (mean arterial blood pressure <60 mm Hg), and total number of interventions.

Results

Weight-based fluid volumes were similar between PACC-MAN and PDM; median and IQR are reported (73.1 mL/kg [59.0-78.7] vs. 87.1 mL/kg [79.4-91.8], P = 0.07). There was no statistical difference in cumulative norepinephrine (PACC-MAN: 33.4 μg/kg [27.1-44.6] vs. PDM: 7.5 [3.3-24.2] μg/kg, P = 0.09). The median percentage of time spent at hypotension was equivalent (PACC-MAN: 6.2% [3.6-7.4] and PDM: 3.1% [1.3-6.6], P = 0.23). Urine outputs were similar between PACC-MAN and PDM (14.0 mL/kg vs. 21.5 mL/kg, P = 0.13).

Conclusion

Automated resuscitation achieves equivalent resuscitation outcomes to direct human intervention in this shock model. This study provides the first translational experience with the PACC-MAN system versus PDM.

Для цитирования: Sanin Gloria D, Cambronero Gabriel E, Wood Elizabeth C, Patterson James W, Lane Magan R, Renaldo Antonio C, Laingen Bonnie E, Rahbar Elaheh, Adams Jason Y, Johnson Austin, Neff Lucas P, Williams Timothy K. MAN VERSUS MACHINE: PROVIDER DIRECTED VERSUS PRECISION AUTOMATED CRITICAL CARE MANAGEMENT IN A PORCINE MODEL OF DISTRIBUTIVE SHOCK.. Shock (Augusta, Ga.). 2024. DOI: 10.1097/shk.0000000000002345.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.