MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11356-017-9894-4

Медицинская библиотека · Environmental science and pollution research international · 2017

Monitoring of selected pharmaceuticals in surface waters of Croatia.

Ivešić Martina, Krivohlavek Adela, Žuntar Irena, Tolić Sonja, Šikić Sandra, Musić Valerija, Pavlić Ivan, Bursik Andrea, Galić Nives

СтатьяПеревод в очереди

Аннотация

Sulfonamides, macrolides, torasemide, fumagillin, and chloramphenicol were simultaneously analyzed in surface water samples by using solid-phase extraction (SPE) and reversed-phase (RP) liquid chromatography-electrospray tandem mass spectrometry (LC-ESI-MS/MS). In the pre-concentration and clean-up process, the pH value of samples and volume of the solvent for extraction of analytes from cartridge were optimized. Extraction recoveries were high with values in the range from 62 to 115%. Limits of quantification (LoQ) were in the range from 0.02 to 0.2 μg L-1. Repeatability of the method was evaluated at LoQ and expressed as relative standard deviation (RSD). Calculated RSDs were low with values in the range from 2.4 to 14.5%. The method was successfully applied for analysis of surface water real samples. Samples were collected along the rivers in Croatia on four sampling sites in 2012 in Danube catchment areas, 19 sampling sites in Danube and Adriatic catchment areas in 2013, and another 19 places in 2014. Altogether, 20 target compounds were analyzed in 148 water samples and detected in 31 samples in range (0.1-5.3) μg L-1 or in 20.1% of samples. The most frequent and highest concentrations were detected for macrolide antibiotics. This is the first attempt of such monitoring in surface waters in Croatia.

Для цитирования: Ivešić Martina, Krivohlavek Adela, Žuntar Irena, Tolić Sonja, Šikić Sandra, Musić Valerija, Pavlić Ivan, Bursik Andrea, Galić Nives. Monitoring of selected pharmaceuticals in surface waters of Croatia.. Environmental science and pollution research international. 2017. DOI: 10.1007/s11356-017-9894-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.