DOI 10.23736/s0375-9393.21.15517-8
Safety and efficacy of remimazolam compared with propofol in induction of general anesthesia.
Аннотация
BACKGROUND
Remimazolam is a new ultrashort acting benzodiazepine anesthetic which has predictable sedative duration and rapid recovery in gastrointestinal endoscopy. Propofol is a commonly used intravenous anesthetic in clinical work which also has rapid action, short action time and rapid recovery. To date, there have been relatively few articles comparing the two for general anesthesia induction. So, we conducted a randomized trial to evaluate whether remimazolam is superior to propofol during anesthesia induction in terms of efficacy and safety.
METHODS
One hundred and eighty nine ASA I or II patients scheduled for elective surgery were divided into four groups: remimazolam 0.2 mg/kg (R1 group), 0.3 mg/kg (R2 group), 0.4 mg/kg (R3 group), and propofol group (P group). All patients were anesthetized with single shots of experimental drugs during induction period. Efficacy was measured by completing the induction of anesthesia without rescue sedation; and safety was defined as no severe adverse events.
RESULTS
Success induction rates in remimazolam groups were 89% (R1 group), 94% (R2 group) and 100% (R3 group) while success induction rate in P group was 100%. Hypotension rates during induction were lower in R1 group (13%) and R2 group (24%) compared with P group (44%). Hypotension rate in R3 group (34%) was similar to propofol (44%). Injection site pain in group P was 27% while no pain was observed in remimazolam groups.
CONCLUSIONS
Remimazolam is a safe and effective sedative drug during induction with less adverse effects for general anesthesia in ASA I or II patients.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.