Gauze pledgetting versus endoscopic-guided aerosolized spray for nasal anesthesia before transnasal EGD: a prospective, randomized study.
Аннотация
BACKGROUND
Methods and efficacy of nasal anesthesia before ultrathin transnasal EGD (UT-EGD) are crucial for patient tolerance.
OBJECTIVE
To compare patient tolerance, safety, and adverse events between cotton-tipped applicator primed gauze pledgetting (CTGP) and endoscopic-guided aerosolized spray (EGAS) methods of nasal anesthesia.
DESIGN
We performed a prospective, randomized-controlled trial to compare procedural discomforts, optical quality, total procedure time, and adverse events between the CTGP and EGAS methods.
SETTING
A large, tertiary referral hospital in Taiwan.
PATIENTS: A total of 240 consecutive patients with epigastric discomfort were included in the study.
INTERVENTION: The author performed all standardized nasal anesthesia and UT-EGD using a 5.9-mm diameter transnasal endoscope.
MAIN OUTCOME MEASUREMENTS: Technical success, patient tolerability profiles, optical quality, total procedure time, and adverse events.
RESULTS
There was no statistical difference in insertion failure rates between the 2 methods (CTGP 0% vs EGAS 5%, P = .07). When compared with the EGAS method, CTGP reduced pain during insertions through the inferior nasal meatus (3.4 +/- 0.5 vs 3.2 +/- 0.4, P = .006), middle nasal meatus (4.0 +/- 0.7 vs 3.4 +/- 0.5, P = .002), and upper esophageal sphincter (2.9 +/- 0.7 vs 2.6 +/- 0.8, P = .005). CTGP elicited less unpleasant taste, fewer gagging episodes, and less throat pain after examination. Both methods had similar safe hemodynamic profiles, low epistaxis rates (0% vs 2%, P = .46), and comparable visual capacity and procedure time. Although similar proportions of patients in both groups would like to receive the same procedure the next time, CTGP had a higher overall tolerance.
CONCLUSION
Compared with the EGAS method, CTGP achieved a better tolerability profile and elicited less bad taste, fewer gagging episodes, and less throat pain after UT-EGD in Taiwanese patients.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.