m+Medelevator.RU
← Поиск публикаций
Journal of hypertension · 2020

Favorable effect of catheter ablation on nocturnal hypertension in patients with paroxysmal atrial fibrillation.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Wada Tadashi, Sakuragi Satoru, Saito Takaaki, Kawaguchi Tatsuto, Kodera Nobuhisa, Iida Toshihiro, Yamada Takashi, Nakashima Mitsutaka, Koide Yuji, Kawamoto Kenji, Tanakaya Machiko, Katayama Yusuke, Ito Hiroshi

Аннотация

OBJECTIVES: The current study was performed to determine whether pulmonary vein isolation (PVI) improves nocturnal hypertension in patients with paroxysmal atrial fibrillation (PAF).

BACKGROUND: Abnormal night-time blood pressure (BP) fluctuation is a risk factor for atrial fibrillation. Imbalance of autonomic nervous function is a risk factor common to both of these abnormalities. PVI can reportedly modify the autonomic nervous function balance in patients with atrial fibrillation.

METHODS: The study population comprised 50 consecutive patients (mean age, 69.8 ± 7.5 years; 35.0% male) with PAF scheduled for PVI. Both 24-h ambulatory BP monitoring and heart rate variability analysis were performed before and at 3 months after PVI.

RESULTS: Patients were classified into two groups according to the presence of nocturnal BP dipping before PVI: the normal dipping group (n = 27) and the nondipping group (n = 23). The low-frequency spectrum power and the ratio of low-frequency spectrum power to high-frequency spectrum power (low-frequency spectrum/high-frequency spectrum) were higher in the nondipping than the normal dipping group (low-frequency spectrum: 219.9 ± 210.2 vs. 92.7 ± 50.5 ms, respectively, P = 0.03; low-frequency spectrum/high-frequency spectrum: 1.8 ± 1.9 vs. 0.9 ± 0.8, respectively, P = 0.05). In the nondipping group, the elevated night-time BP disappeared in eight (35%) patients at 3 months after PVI, which was associated with an increase in high-frequency spectrum power. These patients did not develop atrial fibrillation recurrence during follow-up (mean, 568 ± 218 days).

CONCLUSION: Among patients with PAF, the nondipping group showed greater sympathetic activity (higher low-frequency spectrum power and low-frequency spectrum/high-frequency spectrum) than the dipping group. Restoration of BP dipping after PVI is associated with increased parasympathetic activity (higher high-frequency spectrum power) and reduced recurrence of arrhythmic events.

Предметные рубрики MeSH