DOI 10.1021/jf000638u

Медицинская библиотека · Journal of agricultural and food chemistry · 2000

Determination of phylloquinone and menaquinones in animal products with fluorescence detection after postcolumn reduction with metallic zinc.

Koivu-Tikkanen T J, Ollilainen V, Piironen V I

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A high-performance liquid chromatographic (HPLC) method for the determination of phylloquinone and menaquinones in foods of animal origin is described. The K vitamers were quantified with a fluorescence detector after postcolumn reduction with metallic zinc using K1(25) as an internal standard. Extraction was done either with 2-propanol-hexane (meat and fish products) or with acid hydrolysis method (dairy products). Prior to quantification, sample extracts were purified by semipreparative HPLC; in addition, the fats of cheese and rainbow trout samples were removed with lipase hydrolysis. By this method the phylloquinone and menaquinones (MK-4 to MK-10) present in a few representative samples of different animal food groups were determined. HPLC-MS was used to confirm the identification of K vitamers. Long-chain menaquinones were found from bovine and pig livers as well as from various cheeses. The total vitamin K contents calculated as the sum of quantified K vitamers were in general low (mean content 10-100 ng/g); the highest amount was analyzed in chicken meat (600 ng/g).

Для цитирования: Koivu-Tikkanen T J, Ollilainen V, Piironen V I. Determination of phylloquinone and menaquinones in animal products with fluorescence detection after postcolumn reduction with metallic zinc.. Journal of agricultural and food chemistry. 2000. DOI: 10.1021/jf000638u.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.