DOI 10.1016/j.chroma.2024.464711
Determination of solvation parameter model compound descriptors by gas chromatography.
Аннотация
The solvation parameter model uses five system independent descriptors to characterize compound properties defined as excess molar refraction, E, dipolarity/polarizability, S, hydrogen-bond acidity, A, hydrogen-bond basicity, B, and the gas-liquid partition constant at 25 °C on n-hexadecane, L, to model transfer properties in gas-condensed phase biphasic systems. The E descriptor for compounds liquid at 20 °C is available by calculation using a refractive index value while E for solid compounds at 20 °C and the S, A, B, and L descriptors are determined by experiment. As a single-technique approach, it is shown that with up to 20 retention factor measurements on four columns comprising a poly(siloxane) containing methyloctyl or dimethyldiphenylsiloxane monomers (SPB-Octyl or HP-5), a poly(siloxane) containing methyltrifluoropropylsiloxane monomers (Rtx-OPP or DB-210), a poly(siloxane) containing bis(cyanopropylsiloxane) monomers (HP-88 or SGE BPX-90), and a poly(ethylene glycol) stationary phase (DB-WAXetr or HP-INNOWAX) are suitable for assigning the S, A, and L descriptors. Using the descriptors in the updated WSU compound descriptor database as target values the average absolute error in the descriptor assignments for 52 varied compounds in the temperature range 60-140 °C was 0.072 for E, 0.016 for S, 0.008 for A, and 0.022 for L corresponding to 30 %, 3.5 %, and 0.6 % as a relative average absolute error for E, S, and L, respectively. For the higher temperature range of 160-240 °C and 34 varied compounds that are liquid at 20 °C the average absolute error for the S, A and L descriptors was 0.026, 0.020, and 0.031, respectively, with the largest relative average absolute error for S of 3.2 % (< 1 % for the L descriptor). For 35 varied compounds that are solid at 20 °C the relative absolute error for the E, S, A, and L descriptors in the higher temperature range was 0.068, 0.035, 0.020, and 0.020, respectively, with a relative average absolute error for E (6.5 %), S (3.5 %) and L (0.88 %). The S, A, and L descriptor can be accurately assigned on the four-column system over a wide temperature range. The E descriptor for solid compounds at 20 °C exhibits greater variability than desirable. The B descriptor cannot be assigned by the four-column system, which lack hydrogen-bond acid functional groups, and is only poorly assigned on the weak hydrogen-bond acid ionic liquid column SLB-IL100.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.