MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jelectrocard.2021.12.001

Медицинская библиотека · Journal of electrocardiology · 2021

Enhancing electrocardiographic analysis by combining a high-resolution 12-lead ECG with novel software tools.

Barcos Javier C, Humphreys Juan D, Tello Santacruz Iván A, Guzman Juan P, Fernández Recalde María L, Avaca Horacio A, Cáceres Monié César R

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Signal-averaged electrocardiography is a non-invasive, computerized technique that amplifies, filters, and averages cardiac electrical signals reducing contaminating noise to obtain a high-resolution record. The most widely used signal averaging (SA) method involves a bipolar X, Y, and Z orthogonal lead system. Information is limited regarding its application in the standard resting 12-lead ECG. A novel system combining a high-resolution 12-lead ECG (HR-ECG) registered by SA with advanced analysis tools is presented.

HISTORY: Original programming of a commercially available signal-averaged HR-ECG device was modified, introducing more exhaustive electrocardiographic assessment instruments.

DESCRIPTION: Using SA techniques and placing surface electrodes in the standard 12-lead ECG positions, a HR-ECG is acquired within a bandwidth of 0.25 to 262 Hz at a rate of 1000 samples per second. It is advisable to average at least 200 cycles, taking three to five minutes to record. The package includes different optional high-frequency filters, manual calipers, zoom/superimposing/amplification functions.

CLINICAL ROLE: The main strength lies in obtaining a low noise HR-ECG with zooming capabilities without definition loss. Other potential advantages are the greater ease in performing high precision analysis and comparing different ECG leads simultaneously.

CURRENT PROBLEMS: The primary limitation is the inability to document intermittent or dynamic electrocardiographic disorders because of averaging similar electrical cardiac cycles.

FUTURE DEVELOPMENTS: Adding artificial intelligence and further refinements in the averaging process could lead to software upgrades.

CONCLUSION

Integrating HR-ECG, obtained through SA techniques, with novel advanced analysis tools can enhance the ability to detect electrocardiographic disorders of permanent expression expeditiously.

Для цитирования: Barcos Javier C, Humphreys Juan D, Tello Santacruz Iván A, Guzman Juan P, Fernández Recalde María L, Avaca Horacio A, Cáceres Monié César R. Enhancing electrocardiographic analysis by combining a high-resolution 12-lead ECG with novel software tools.. Journal of electrocardiology. 2021. DOI: 10.1016/j.jelectrocard.2021.12.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.