DOI 10.1016/j.ijrobp.2014.03.022

Медицинская библиотека · International journal of radiation oncology, biology, physics · 2014

Comparison of radiation-induced normal lung tissue density changes for patients from multiple institutions receiving conventional or hypofractionated treatments.

Diot Quentin, Marks Lawrence B, Bentzen Soren M, Senan Suresh, Kavanagh Brian D, Lawrence Michael V, Miften Moyed, Palma David A

Сравнительное исследованиеСтатьяМногоцентровое исследованиеПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To quantitatively assess changes in computed tomography (CT)-defined normal lung tissue density after conventional and hypofractionated radiation therapy (RT).

METHODS AND MATERIALS: The pre-RT and post-RT CT scans from 118 and 111 patients receiving conventional and hypofractionated RT, respectively, at 3 institutions were registered to each other and to the 3-dimensional dose distribution to quantify dose-dependent changes in normal lung tissue density. Dose-response curves (DRC) for groups of patients receiving conventional and hypofractionated RT were generated for each institution, and the frequency of density changes >80 Hounsfield Units (HU) was modeled depending on the fractionation type using a Probit model for different follow-up times.

RESULTS

For the pooled data from all institutions, there were significant differences in the DRC between the conventional and hypofractionated groups; the respective doses resulting in 50% complication risk (TD50) were 62 Gy (95% confidence interval [CI] 57-67) versus 36 Gy (CI 33-39) at <6 months, 48 Gy (CI 46-51) versus 31 Gy (CI 28-33) at 6-12 months, and 47 Gy (CI 45-49) versus 35 Gy (32-37) at >12 months. The corresponding m values (slope of the DRC) were 0.52 (CI 0.46-0.59) versus 0.31 (CI 0.28-0.34) at <6 months, 0.46 (CI 0.42-0.51) versus 0.30 (CI 0.26-0.34) at 6-12 months, and 0.45 (CI 0.42-0.50) versus 0.31 (CI 0.27-0.35) at >12 months (P<.05 for all comparisons).

CONCLUSION

Compared with conventional fractionation, hypofractionation has a lower TD50 and m value, both suggesting an increased degree of normal tissue density sensitivity with hypofractionation.

Для цитирования: Diot Quentin, Marks Lawrence B, Bentzen Soren M, Senan Suresh, Kavanagh Brian D, Lawrence Michael V, Miften Moyed, Palma David A. Comparison of radiation-induced normal lung tissue density changes for patients from multiple institutions receiving conventional or hypofractionated treatments.. International journal of radiation oncology, biology, physics. 2014. DOI: 10.1016/j.ijrobp.2014.03.022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.