Long-Term Clinical Impact of Paravalvular Leak Following Transcatheter Aortic Valve Implantation.
Аннотация
Background
Paravalvular leak (PVL) was initially recognized as one of the most common complications after transcatheter aortic valve implantation (TAVI) and has been linked to adverse clinical outcomes, including mortality. This study aims to assess the long-term clinical effects of PVL in patients undergoing TAVI with the latest generation of transcatheter aortic valves, as part of the national observational prospective multicenter study OBSERVANT II.
Methods
OBSERVANT II included all consecutive patients with severe aortic stenosis who underwent TAVI across 28 Italian centers from December 2016 to September 2018. A total of 2125 patients were included in this analysis and stratified according to the presence of moderate-to-severe PVL (significant PVL, n = 155) versus no/trace-to-mild PVL (no significant PVL, n = 1970). The primary endpoint was 5-year major adverse cardiac and cerebrovascular events (MACCE), including all-cause death, stroke, myocardial infarction, and coronary revascularization. Five-year all cause death and re-hospitalization for heart failure (HF) were the secondary endpoints.
Results
In our cohort, the incidence of moderate-to-severe PVL was 7%. Age, aortic anulus perimeter, and self-expandable valves were determinants of PVL. The risk of MACCE, all-cause death, and re-hospitalization for HF at the 5-year follow-up were not different between the study groups [HR = 1.07 (95% CI: 0.85-1.34) p = 0.571; HR = 1.10 (95% CI: 0.87-1.39) p = 0.435; HR = 1.20 (95% CI: 0.88-1.62) p = 0.245, respectively].
Conclusions
In this analysis of the OBSERVANT II study, moderate/severe PVL was not associated with a higher incidence of MACCE and re-hospitalization for heart failure at the 5-year follow-up.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.