The reliability of transabdominal cervical length measurement in a low-risk obstetric population: Comparison with transvaginal measurement.

Peng Cheng-Ran, Chen Chie-Pein, Wang Kuo-Gon, Wang Liang-Kai, Chen Chen-Yu, Chen Yi-Yung

Клиническое исследованиеСравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To determine the correlation between transabdominal (TA) and transvaginal (TV) cervical length measurement in a low-risk obstetric population in Taiwan.

MATERIALS AND

METHODS

Women with a singleton pregnancy between 20 weeks and 24 weeks of gestation underwent postvoid TA and TV cervical length measurements. Differences between the measurements obtained using the two methods were evaluated.

RESULTS

Two hundred and five women agreed to participate in the study. Paired TA and TV measurements were obtained in 174 women. The mean TA cervical length was 36.0 ± 4.9 mm and the mean TV cervical length was 37.6 ± 5.4 mm. The mean TA cervical length was shorter than the mean TV cervical length by 1.6 mm. The 5(th) percentile of TA and TV cervical length was 29 mm and 29.1 mm, respectively. The discrepancies between the two methods were not significantly correlated with maternal body mass index (BMI). All women with TV cervical length <25 mm had a corresponding TA cervical length <29 mm.

CONCLUSION

The TA cervical length could be obtained in the majority of the low-risk pregnant women in the present study, and the TA cervical length was closely correlated with the TV cervical length. The use of TA ultrasound could be an effective initial tool for cervical length screening in low-risk pregnant women. TA cervical length <29 mm (5(th) percentile) could be used as a cut-off value for further TV ultrasound.

Для цитирования: Peng Cheng-Ran, Chen Chie-Pein, Wang Kuo-Gon, Wang Liang-Kai, Chen Chen-Yu, Chen Yi-Yung. The reliability of transabdominal cervical length measurement in a low-risk obstetric population: Comparison with transvaginal measurement.. Taiwanese journal of obstetrics & gynecology. 2015. DOI: 10.1016/j.tjog.2014.03.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.