MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1183/09031936.00149810

Медицинская библиотека · The European respiratory journal · 2011

In vivo monitoring of cystic fibrosis-like lung disease in mice by volumetric computed tomography.

Wielpütz M O, Eichinger M, Zhou Z, Leotta K, Hirtz S, Bartling S H, Semmler W, Kauczor H-U, Puderbach M, Mall M A

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The onset and spontaneous development of cystic fibrosis (CF) lung disease remain poorly understood. In the present study, we used volumetric computed tomography (VCT) as a new method for longitudinal in vivo monitoring of early lesions and disease progression in CF-like lung disease in β-epithelial Na(+) channel (ENaC)-transgenic (TG) mice. Using a VCT scanner prototype (80 kV, 50 mA·s, scan time 19 s and spatial resolution 200 μm), βENaC-TG mice and wild-type (WT) littermates were examined longitudinally at 10 time-points from neonatal to adult ages, and VCT images were assessed by qualitative and quantitative morphological parameters. We demonstrate that VCT detected early-onset airway mucus obstruction, diffuse infiltrates, atelectasis and air trapping as characteristic abnormalities in βENaC-TG mice. Furthermore, we show that early tracheal mucus obstruction predicted mortality in βENaC-TG mice and that the density of lung parenchyma was significantly reduced at all time-points in βENaC-TG compared with WT mice (median ± sem -558 ± 8 HU in WT versus -686 ± 16 HU in βENaC-TG at 6 weeks of age; p < 0.005). Our study demonstrates that VCT is a sensitive, noninvasive technique for early detection and longitudinal monitoring of morphological abnormalities of CF-like lung disease in mice, and may thus provide a useful tool for pre-clinical in vivo evaluation of novel treatment strategies for CF.

Для цитирования: Wielpütz M O, Eichinger M, Zhou Z, Leotta K, Hirtz S, Bartling S H, Semmler W, Kauczor H-U, Puderbach M, Mall M A. In vivo monitoring of cystic fibrosis-like lung disease in mice by volumetric computed tomography.. The European respiratory journal. 2011. DOI: 10.1183/09031936.00149810.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.